Residential Checklist Email* Address Street Address Address Line 2 City State / Province / Region ZIP / Postal Code AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAnguillaAntarcticaAntigua and BarbudaArgentinaArmeniaArubaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBonaire, Sint Eustatius and SabaBosnia and HerzegovinaBotswanaBouvet IslandBrazilBritish Indian Ocean TerritoryBrunei DarussalamBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCayman IslandsCentral African RepublicChadChileChinaChristmas IslandCocos IslandsColombiaComorosCongo, Democratic Republic of theCongo, Republic of theCook IslandsCosta RicaCroatiaCubaCuraçaoCyprusCzech RepublicCôte d'IvoireDenmarkDjiboutiDominicaDominican RepublicEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEswatini (Swaziland)EthiopiaFalkland IslandsFaroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern TerritoriesGabonGambiaGeorgiaGermanyGhanaGibraltarGreeceGreenlandGrenadaGuadeloupeGuamGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard and McDonald IslandsHoly SeeHondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqIrelandIsle of ManIsraelItalyJamaicaJapanJerseyJordanKazakhstanKenyaKiribatiKuwaitKyrgyzstanLao People's Democratic RepublicLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacauMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorth KoreaNorthern Mariana IslandsNorwayOmanPakistanPalauPalestine, State ofPanamaPapua New GuineaParaguayPeruPhilippinesPitcairnPolandPortugalPuerto RicoQatarRomaniaRussiaRwandaRéunionSaint BarthélemySaint HelenaSaint Kitts and NevisSaint LuciaSaint MartinSaint Pierre and MiquelonSaint Vincent and the GrenadinesSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSint MaartenSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSouth GeorgiaSouth KoreaSouth SudanSpainSri LankaSudanSurinameSvalbard and Jan Mayen IslandsSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTimor-LesteTogoTokelauTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTurks and Caicos IslandsTuvaluUS Minor Outlying IslandsUgandaUkraineUnited Arab EmiratesUnited KingdomUnited StatesUruguayUzbekistanVanuatuVenezuelaVietnamVirgin Islands, BritishVirgin Islands, U.S.Wallis and FutunaWestern SaharaYemenZambiaZimbabweÅland Islands Country Name First Last PhoneProject TypeEnergy Compliance Method*Select OneSelect OnePrescriptive MethodTrade Off MethodSimulated Performance AlternativeEnergy Rating Index2. Mandatory Requirements –All Projects must meet the mandatory requirements of the IECCa. Certificate (R401.3)*Will Complyb. Building thermal envelope (R402.4.1). Seal thermal building envelope to reduce air leakage.*Will Complyc. *Fireplaces (R402.4.2). New wood-burning shall have tight flue dampers, or doors, and outdoor combustion air. Illinois Amendments*Will ComplyN/Ad. Fenestration air leakage (R402.4.3). Windows, sliding glass doors and skylights must have an air infiltration rate of ≤ 0.3 cfm per square foot (1.5 L/s/m2) and swinging doors air infiltration rate of ≤ 0.5 cfm per square foot (2.6 L/s/m2).*Will ComplyN/Ae. Recessed Lighting in thermal envelope (R402.4.5). Must be IC-rated and labelled with air leakage rate ≤ 2.0 cfm (1.5 L/s), at a pressure differential of 1.57 psf (75Pa).*Will ComplyN/Af. Fenestration: Maximum Fenestration U-Factor and SHGC (R402.5). Area-weighted average fenestration U-Factor*Will ComplyN/Ag. Programmable thermostat (R403.1.1) for each HVAC system. Must be capable of daily schedule control.*Will ComplyN/Ah. Heat Pump Supplementary heat (R403.1.2) with supplementary electric-resistance shall have controls.*Will ComplyN/Ai. Ducts, air handlers and filter boxes shall be sealed (R403.3.2). Air handlers need manufacturers air leakage designation of ≤ 2% of design flow rate.(ASHRAE 193).*Will ComplyN/Aj. Duct Testing (R403.3.3). Pressure test to determine air leakage*Will ComplyN/Ak. Mechanical system, piping insulation (R403.4). R3 minimum for > 105°F (41°C) or <55°F (13°C). Piping insulation exposed to weather damage must be protected. Protection must shield from solar radiation. Adhesive tape is banned.*Will ComplyN/Al. Building cavities (R403.3.5). Framing cavities must not be used as ducts or plenums.*Will ComplyN/Am. Heated Water Circulation and temperature maintenance systems (R403.5.1). There must be a circulation pump with the system. Automatic on/off*Will ComplyN/An. Mechanical Ventilation (R403.6). Shall comply with the International Residential Code or International Mechanical Code.*Will ComplyN/Ao. Equipment Sizing and efficiency (R403.7) Heating/Cooling equipment sized per ACCA Manuals S based on building loads calculated in accordance with ACCA Manual J.*Will ComplyN/Ap. Systems serving multiple dwelling units (R403.8). Must comply with sections C403 and C404 of the IECC*Will ComplyN/Aq. Snow melt and ice system controls (R403.9). System automatic on/off controls at pavement temps > 50°F (10°C) and no precipitation falling and outdoor temps > 40°F (4.8°C).*Will ComplyN/Ar. Pool and Permanent Spa Heaters (R403.10.1). Readily accessible on-off switch. Exterior, external and within 3 feet (914mm) of the heater.*Will ComplyN/As. Pool and Permanent Spa Time Switches (R403.10.2). Automatic on/off switch according to schedule. Exceptions - public health standard pumps and solar and waste-heat recovery pool.*Will ComplyN/At. Pool and Permanent Spa Covers (R403.10.3). vapor-retardant or approved means required for outdoor heated pools and outdoor permanent spas. Exception when >75% of heating, > 3months from a HP or onsite RE.*Will ComplyN/Au. Portable spas (R403.11). Controlled by requirements of APSP-14.*Will ComplyN/Av. Lighting Equipment (R404.1) Min. 90% of installed lighting fixtures = high-efficacy lamps as defined in Illinois Amendments.*Will ComplyN/A3. Prescriptive Requirements –Please complete this methoda. General (R402.1) – Building thermal envelope shall comply with the requirements of Sections R402.1.1 through R402.1.5.*Exceptions: o low-energy buildings or portions with the following peak design rate of energy usage < 3.4/h.ft2 (10.7 W/m2) or 1.0 watt/ft2 of floor area for space-conditioning purposes. o Log homes designed in accordance with ICC 400. Will ComplyExemptb. Vapor Retarder (R402.1.1) – Wall assemblies must comply with the vapor retarder requirements in Section R702.7 of the International Residential Code or Section 1405.3 of the International Building Code.*Will ComplyExemptc. Insulation and Fenestration Criteria (R402.1.2)Requirements based of (TableR402.1.2) for Climate ZoneFenestration U-Factor*0.32 (Zone 4)0.30 (Zone 5)N/AGlazed Fenestration SHGC*0.40 (Zone 4A)NR Zone 5AN/ASkylights U-Factor*0.55 (Zone 4 or 5)N/ACeiling R-Value*49 (Zone 4 or 5)N/AWood Frame Wall R-Value*20 or 13+5h (Zone 4 or 5)N/AMass Frame Wall R-Value*8/13 (Zone 4A)13/17 (Zone 5A)N/AFloor R-Value*19 (Zone 4A)30e^2 (Zone 5A)N/ABasement R-Value*10/13 (Zone 4 or 5)N/ASlab R-Value & Depth*10, 2ft (Zone 4 or 5)N/ACrawl Space R-Value*10/13 (Zone 4A)15/19 (Zone 5A)N/Ad. R-Value Computation (R402.1.3) – Insulation material in layers need to be summed to calculate the R-Value.*Blown-in insulationCavity insulationContinuous insulationOther building materialsInsulated sidingN/Ae. U-Factor alternative (R402.1.4)*If assembly value ≦ (Table R402.1.4), then use Table R402.1.2).Assembly ValueN/Af. Ceilings with Attic Spaces (R402.2.1)*R-38 Insulation - If R-30 is installed over 100%, R-38 is satisfied.R-49 insulation - If R-38 is installed over 100%, R-49 is satisfied.N/Ag. Ceilings without Attic Spaces (R402.2.2)*R-30 Insulation Limited to 500 square feet (46m2) Or 20% total insulated ceiling area, whichever is lessN/Ah. Eave Baffle (R402.2.3)*Baffle installed adjacent to soffit and eave vents of opening equal or greater than size of vent and extended over the top of the attic insulation.N/Ai. Access hatches and doors (R402.2.4)*Must be weather-stripped and insulated to the level equivalent of the surroundingsN/Aj. Mass Walls (R402.2.5) – as a component of building thermal envelope*Above-ground walls.Any wall with a heat capacity ≧ 6 Btu/ft2 ºF (123 kJ/m2 •K)N/Ak. Steel-frame ceilings, walls and floors (R402.2.6) – must comply with insulation requirements of Table R402.2.6 or the U-factor requirements of Table R402.1.4.*Table R402.1.4.Table R402.2.6.Steel-frame series-parallel path calculation methodN/Al. Walls With Partial Structural Sheathing (R402.2.7) ≦40% of continuous insulation*≦40% of continuous insulationRequired R-Value≦R -3N/Am. Floors (R402.2.8) – framing-cavity insulation maintain permanent contact with the underside of the subfloor decking.*Alternate insulation topside of sheathingContinuous insulation bottom side of floor framingCombined insulation wood-frame wall ≧Table R402.1.2N/An. Basement Walls (R402.2.9) insulate from the top of basement down to the criteria*10 feet (3048 mm) below grade Basement floor.Unconditioned basements - R402.1.2 and R402.2.8.N/Ao. Slab-On Grade Floors (R402.2.10)*Floor surface < 12 inches (305mm) comply with (Table R402.1.2):Distance provided comply with (Table R402.1.2)N/Ap. Crawl Space Walls (R402.2.11) - crawl space walls shall be insulated provided that the crawl space is not vented to the outdoors.*Insulation shall be permanently fastened to the wallExtend downward from the floor to the finished grade elevation.Vertically or horizontally ≧ an additional 24 inches (610 mm)Exposed earth covered with a continuous Class I vapor retarderVapor retarder Joints overlap by 6 inches (153 mm) and be sealed or tapedVapor retarder edges ≧ 6 inches (153 mm) up stem wallsN/Aq. Masonry Veneer (R402.2.12) – No requirement for horizontal portion of a foundation that supports a masonry veneer.*Will ComplyN/Ar. Sunroom Insulation (R402.2.13) – meet insulation requirement for code*ComplyN/As. Fenestration (R402.3) - comply with Sections R402.3.1 through to R402.3.5.*Select one's that apply U-factor (R402.3.1) requirements Glazed Fenestration SHGC > 50% Dynamic glazing Table R402.1.2 SHGC requirements 50% Exception - Dynamic glazing SHGC comply with (Table R402.1.2.) Glazed Fenestration Exemption (R402.3.3) ≦ 15 square feet (1.4 m2) of glazed fenestration per dwelling unit no Section R402.1.2. Opaque Door Exemption (R402.3.4) Sunroom Fenestration (R402.3.5) Enclosing conditioned space complies with fenestration code Sunroom with thermal isolation from conditioned space complies with the building thermal envelope code N/A t. Insulation (R403.3.1) – Supply and return ducts*Select one's that apply Supply ducts ≥ 3 inches (76mm in diameter) in attic ≥ R-8: Supply ducts < 3 inches (76mm in diameter) in attic ≥ R-6 Supply ducts = 3 inches (76mm in diameter) in other parts of building ≥ R-6 Supply ducts < 3 inches (76mm in diameter) in other parts of building ≥ R-4.2 N/A u. Duct Leakage (R403.3.4)*Rough-in testPostconstruction testN/A